EMC offers up-to-date EMC D-PSC-MN-01 practice material consisting of three formats that will prove to be vital for you. You can easily ace the D-PSC-MN-01 exam on the first attempt if you prepare with this material. The EMC D-PSC-MN-01 Exam Dumps have been made under the expert advice of 90,000 highly experienced professionals from around the globe. They assure that anyone who prepares from it will get EMC D-PSC-MN-01 certified on the first attempt.
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
Topic 4 |
|
>> D-PSC-MN-01 Valid Test Blueprint <<
In addition to the free download of sample questions, we are also confident that candidates who use D-PSC-MN-01 study materials will pass the exam at one go. D-PSC-MN-01 study materials are revised and updated according to the latest changes in the syllabus and the latest developments in theory and practice. Regardless of your weak foundation or rich experience, D-PSC-MN-01 study materials can bring you unexpected results. In the past, our passing rate has remained at 99%-100%. This is the most important reason why most candidates choose D-PSC-MN-01 Study Materials. Failure to pass the exam will result in a full refund. But as long as you want to continue to take the D-PSC-MN-01 exam, we will not stop helping you until you win and pass the certification.
NEW QUESTION # 122
Which aspect is crucial when cabling nodes in a PowerScale installation?
Answer: B
NEW QUESTION # 123
After finishing the installation of a Dell EMC PowerScale Gen 6 cluster, a customer asks the platform engineer to demonstrate the proper way to remove and replace the front node bezel. They remove the bezel successfully.
What is the correct way to replace the bezel?
Answer: C
Explanation:
After removing the bezel from a Dell EMC PowerScale Gen 6 node, it's important to reinstall it correctly to maintain proper airflow and protect the hardware.
Steps to Replace the Bezel:
* Alignment:
* Align Bezel Ends with Clips:
* Position the bezel in front of the node chassis.
* Ensure that the ends of the bezel are aligned with the corresponding clips or slots on the chassis.
* Attachment:
* Press the Bezel Center:
* Gently but firmly press the center of the bezel.
* This action engages the clips on both ends simultaneously, securing the bezel to the chassis.
Why Option D is Correct:
* Proper Technique:
* Aligning the bezel ends with the clips ensures correct positioning.
* Pressing the bezel center allows for even engagement of the clips, preventing misalignment or damage.
Why Other Options Are Incorrect:
* Option A:
* Checking for red LEDs is good practice but not directly related to bezel replacement.
* Securing with thumb screws is not applicable as Gen 6 bezels typically do not use thumb screws.
* Option B:
* Pressing the left side and then the right side may not ensure proper alignment and could cause the bezel to be uneven.
* Option C:
* Pushing on the bezel ends without proper alignment may result in the clips not engaging correctly.
Dell PowerScale References:
* Dell EMC PowerScale Hardware Installation Guide:
* Section on Bezel Installation and Removal:
* Provides instructions and illustrations on how to properly replace the bezel.
* Emphasizes aligning the bezel and pressing the center for secure attachment.
* Best Practices:
* Ensure that no cables or obstructions are in the way before replacing the bezel.
* Verify that the bezel is flush with the chassis after installation.
Additional Notes:
* Airflow Management:
* Proper bezel installation is crucial for maintaining optimal airflow and cooling within the node.
* Protection:
* The bezel protects internal components from dust and physical damage.
NEW QUESTION # 124
What is the first step in planning the installation of a PowerScale cluster?
Answer: D
NEW QUESTION # 125
A platform engineer must replace a failed chassis on a Dell PowerScale Gen6 cluster. What must the engineer do after powering off the nodes?
Answer: B
Explanation:
When replacing a failed chassis in a Dell PowerScale Gen6 cluster, it's critical to preserve the data and configuration by maintaining the exact placement of the drive sleds. After powering off the nodes, the engineer should:
* Remove Drive Sleds:
* Carefully remove each drive sled from the failed chassis.
* Label for Identification:
* Label each drive sled with its corresponding slot number or unique identifier.
* Install New Chassis:
* Mount the new chassis in the rack where the failed one was located.
* Reinstall Drive Sleds:
* Insert the labeled drive sleds into the same slots in the new chassis.
* Power On Nodes:
* Power on the nodes and verify that they boot correctly and rejoin the cluster.
This procedure ensures that the drives remain in their original configuration, preserving data integrity and cluster settings. There's no need to transfer motherboards or reimage drives, as these actions could disrupt cluster operations and lead to data loss.
References:
* Dell PowerScale Hardware Replacement Guide- Chassis Replacement Procedures
* Dell PowerScale OneFS Administration Guide- Best Practices for Hardware Maintenance
* Dell Knowledge Base Article- Preserving Drive Order During Chassis Replacement
NEW QUESTION # 126
How should a technician proceed after installing a new FRU in a PowerScale node?
Answer: C
NEW QUESTION # 127
......
Through our investigation and analysis of the real problem over the years, our D-PSC-MN-01 prepare questions can accurately predict the annual D-PSC-MN-01 exams. And the D-PSC-MN-01 quiz guide’s experts still have the ability to master propositional trends. Believe that such a high hit rate can better help users in the review process to build confidence, and finally help users through the qualification examination to obtain a certificate. All in all, we want you to have the courage to challenge yourself, and our D-PSC-MN-01 Exam Prep will do the best for the user's expectations.
D-PSC-MN-01 New Study Notes: https://www.practicevce.com/EMC/D-PSC-MN-01-practice-exam-dumps.html
© 2024 NXT Nerd. All Rights Reserved